Room Systems |
Gemini Profile Room Ionization Controller
| | The system controller maintains contact between each emitter module and itself to verify system operations. Under normal conditions, the unit displays "Status Normal" to provide assurance that no fault conditions exist. Should a system fault occur, the controller identifies the address and type on its LCD.
Operating mode and pulse frequency are adjusted from the system controller.
Adjustment to ion output and balance can be made to individual emitter modules or to the entire group (Steady State or Pulse mode) using the system controller or the hand-held remote control transmitter.
Our patented miswire protection design speeds and simplifies installation and prevents wiring problems.
A data port for communications to a PC or facility monitoring system is provided.
SIMCO provides professional install-ation, a two-year warranty, and factory-direct technical support from our worldwide manufacturing facilities. Free
system training is provided after installation.
Features include:
- Microcontroller Intelligence
- Self-monitoring and adjusting
- Fully integrated two-way communications network
- Continual polling of emitter modules and display of operating status
- Pulse or Steady-State DC operation
- Data port for communications to a PC or facility monitoring system
|
|
| Typical Use / Specifications / Download Files |
Specifications: | |
| Size |
16.25" x 8.75" x 4.5" (W x L x D) (41.7 x 22.4 x 11.5 cm) |
| Weight |
25 lbs. (11.3 kg) |
| Input |
Universal 100 to 240 VAC, 50/60 Hz, 15 Amp max |
| Capacity |
30 or 100 emitter modules |
| Operating Mode |
Steady State or Pulse DC |
| Pulse Rate |
0.5 to 12-second timing control of ionization output; centrally controlled to avoid timing conflicts |
| Output Connector |
10 each, 8-pin RJ-45 telephone-type modular jacks |
| Wiring Run |
Up to 800 ft. |
| Controls |
Lockout key switch has STANDBY- SETUP-RUN modes |
|
Recessed push button selection of system setup mode |
|
Two-button menu scroll |
|
Two-button function adjustment |
|
|